9AZV
CH67 Fab bound to A/Massachusetts/1/1990 influenza hemagglutinin head with a G189E mutation (2)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-11-24 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.97918 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 76.277, 93.467, 108.852 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.030 - 3.160 |
R-factor | 0.2421 |
Rwork | 0.237 |
R-free | 0.28730 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.002 |
RMSD bond angle | 0.484 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.030 | 3.350 |
High resolution limit [Å] | 3.160 | 3.160 |
Number of reflections | 13883 | 2181 |
<I/σ(I)> | 10.81 | 2.18 |
Completeness [%] | 99.7 | |
Redundancy | 5.8 | |
CC(1/2) | 0.996 | 0.901 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291 | 20% PEG 8K, 100 mM HEPES, pH 7, 100 mM MgSO4 |