9NK5
[0,7,12-->14] Shifted tensegrity triangle with an (arm,center,arm) distribution of (0,7,12) base pairs and 2 nt sticky ends containing a semi-junction that becomes left-handed
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 17-ID |
| Synchrotron site | APS |
| Beamline | 17-ID |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-02-26 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 1.000000 |
| Spacegroup name | H 3 |
| Unit cell lengths | 112.776, 112.776, 68.087 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 39.680 - 4.580 |
| R-factor | 0.1966 |
| Rwork | 0.195 |
| R-free | 0.23310 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.005 |
| RMSD bond angle | 0.748 |
| Data reduction software | autoPROC |
| Data scaling software | STARANISO |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.21.1_5286) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 39.682 | 39.682 | 5.149 |
| High resolution limit [Å] | 4.580 | 9.406 | 4.584 |
| Number of reflections | 1459 | 208 | 210 |
| <I/σ(I)> | 10.5 | ||
| Completeness [%] | 86.2 | ||
| Redundancy | 10.3 | ||
| CC(1/2) | 0.997 | 0.997 | 0.349 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100 mM MOPS, 1.25 M magnesium sulfate |