9K34
Human IgG1 Fc fragments, mutant (2CT1.9)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 11C |
| Synchrotron site | PAL/PLS |
| Beamline | 11C |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2024-10-03 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 0.97942 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 75.988, 101.630, 146.793 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 14.990 - 3.000 |
| R-factor | 0.2172 |
| Rwork | 0.214 |
| R-free | 0.27930 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.891 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((1.19.2_4158: ???)) |
Data quality characteristics
| Overall | Inner shell | Outer shell | |
| Low resolution limit [Å] | 50.000 | 50.000 | 3.050 |
| High resolution limit [Å] | 2.990 | 8.130 | 3.000 |
| Rmerge | 0.231 | 0.089 | 0.779 |
| Rmeas | 0.255 | 0.096 | 0.920 |
| Rpim | 0.105 | 0.036 | 0.472 |
| Number of reflections | 22816 | 1300 | 989 |
| <I/σ(I)> | 3.2 | ||
| Completeness [%] | 96.6 | 99.1 | 84.2 |
| Redundancy | 5.3 | 6.8 | 3.1 |
| CC(1/2) | 0.958 | 0.994 | 0.092 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 291 | 50mM HEPES pH 7.0, 10% PEG 3350 |