Truncated RNF112, nucleotide-free
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL02U1 |
Synchrotron site | SSRF |
Beamline | BL02U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-09-21 |
Detector | DECTRIS EIGER2 S 9M |
Wavelength(s) | 0.97918 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 243.489, 39.766, 48.773 |
Unit cell angles | 90.00, 100.03, 90.00 |
Refinement procedure
Resolution | 28.380 - 2.090 |
R-factor | 0.226 |
Rwork | 0.226 |
R-free | 0.23160 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 0.914 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX ((1.19_4092: 000)) |
Refinement software | PHENIX ((1.19_4092: 000)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 28.380 | 2.200 |
High resolution limit [Å] | 2.090 | 2.090 |
Number of reflections | 26331 | 3912 |
<I/σ(I)> | 8.3 | 2.5 |
Completeness [%] | 95.6 | 98.4 |
Redundancy | 3.8 | 3.3 |
CC(1/2) | 0.998 | 0.922 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291.15 | PEG 3350, Tacsimate pH 6.0, |