Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SLS BEAMLINE X10SA |
| Synchrotron site | SLS |
| Beamline | X10SA |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-10-18 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.99998 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 65.920, 68.208, 421.060 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 210.530 - 2.380 |
| R-factor | 0.23625 |
| Rwork | 0.236 |
| R-free | 0.28547 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.003 |
| RMSD bond angle | 1.344 |
| Data reduction software | autoPROC |
| Data scaling software | autoPROC ((Version 1.1.7)) |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 210.530 | 2.420 |
| High resolution limit [Å] | 2.380 | 2.380 |
| Number of reflections | 78066 | 3786 |
| <I/σ(I)> | 14.5 | |
| Completeness [%] | 99.9 | |
| Redundancy | 8.2 | |
| CC(1/2) | 0.990 | 0.910 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | BICINE: 0.10 M pH:9.00 ; LiSO4: 0.16M ; PEG 2K MME: 24 %w/v |