Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ALS BEAMLINE 5.0.1 |
| Synchrotron site | ALS |
| Beamline | 5.0.1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-09-29 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 1 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 44.780, 53.866, 114.040 |
| Unit cell angles | 90.00, 101.30, 90.00 |
Refinement procedure
| Resolution | 55.910 - 1.770 |
| R-factor | 0.2212 |
| Rwork | 0.219 |
| R-free | 0.26490 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.020 |
| Data reduction software | autoPROC |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | BUSTER (2.11.8 (23-JAN-2024)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 55.910 | 1.860 |
| High resolution limit [Å] | 1.770 | 1.770 |
| Rmerge | 0.056 | 1.210 |
| Rmeas | 0.067 | 1.517 |
| Rpim | 0.037 | 0.898 |
| Total number of observations | 135320 | 14043 |
| Number of reflections | 43484 | 5838 |
| <I/σ(I)> | 9 | 0.7 |
| Completeness [%] | 82.5 | |
| Redundancy | 3.1 | 2.4 |
| CC(1/2) | 0.999 | 0.416 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 291 | 25% Peg 1500, 0.1M MIB pH 7.0 |