Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8YKU

PaThiL in complex with AMP-PNP and TMP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX1
Synchrotron siteAustralian Synchrotron
BeamlineMX1
Temperature [K]100
Detector technologyPIXEL
Collection date2022-02-18
DetectorDECTRIS EIGER X 9M
Wavelength(s)0.953721724543
Spacegroup nameP 61 2 2
Unit cell lengths118.590, 118.590, 131.870
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution51.350 - 2.170
R-factor0.1698
Rwork0.169
R-free0.17590
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle0.925
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareMOLREP
Refinement softwarePHENIX (Version 1.18.2-3874)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]51.3502.248
High resolution limit [Å]2.1702.170
Rpim0.042
Number of reflections295492895
<I/σ(I)>17.37
Completeness [%]100.0100
Redundancy33.2
CC(1/2)0.9980.917
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293.150.2M calcium acetate hydrate, 0.1M sodium cacodylate pH 6.5, 40% (v/v) PEG 300

227344

PDB entries from 2024-11-13

PDB statisticsPDBj update infoContact PDBjnumon