Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8WZO

Parkin in complex with phospho NEDD8

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID30B
Synchrotron siteESRF
BeamlineID30B
Temperature [K]100
Detector technologyPIXEL
Collection date2023-09-28
DetectorDECTRIS EIGER X 9M
Wavelength(s)0.8731
Spacegroup nameI 1 2 1
Unit cell lengths77.976, 47.747, 127.859
Unit cell angles90.00, 105.38, 90.00
Refinement procedure
Resolution40.947 - 2.250
Rwork0.207
R-free0.24850
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5n2w
RMSD bond length0.004
RMSD bond angle1.026
Data reduction softwarexia2
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0258)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.5202.320
High resolution limit [Å]2.2502.250
Number of reflections217721974
<I/σ(I)>8.4
Completeness [%]99.8
Redundancy4.3
CC(1/2)0.9930.643
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION2770.02 M Sodium/potassium phosphate, 0.1 M Bis-Tris propane, 7.5, 20% w/v PEG 3350

225946

PDB entries from 2024-10-09

PDB statisticsPDBj update infoContact PDBjnumon