8WPT
Truncated mutant (1-171) of ferritin from Ureaplasma diversum
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL02U1 |
Synchrotron site | SSRF |
Beamline | BL02U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-10-06 |
Detector | DECTRIS EIGER2 S 9M |
Wavelength(s) | 0.9791 |
Spacegroup name | F 4 3 2 |
Unit cell lengths | 181.600, 181.600, 181.600 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 32.103 - 2.360 |
R-factor | 0.1876 |
Rwork | 0.182 |
R-free | 0.24090 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 0.970 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX ((1.15.2_3472: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 52.420 | 2.420 |
High resolution limit [Å] | 2.360 | 2.360 |
Rmerge | 0.161 | 2.007 |
Rmeas | 0.163 | 2.033 |
Rpim | 0.026 | 0.324 |
Total number of observations | 30778 | |
Number of reflections | 19904 | 793 |
<I/σ(I)> | 24.4 | 2.8 |
Completeness [%] | 99.9 | |
Redundancy | 37.6 | 38.8 |
CC(1/2) | 1.000 | 0.849 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | Bicine, MgCl2 |