8W93
Azumapecten Farreri homopolymeric ferritin (ApF) mutant-H2KE
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL18U1 |
Synchrotron site | SSRF |
Beamline | BL18U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-01-12 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.9785 |
Spacegroup name | I 4 3 2 |
Unit cell lengths | 152.679, 152.679, 152.679 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 26.180 - 2.090 |
R-factor | 0.1796 |
Rwork | 0.178 |
R-free | 0.20220 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 0.773 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | MOLREP |
Refinement software | PHENIX ((1.20.1_4487: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 26.180 | 2.165 |
High resolution limit [Å] | 2.090 | 2.091 |
Number of reflections | 18289 | 1776 |
<I/σ(I)> | 18.12 | |
Completeness [%] | 99.9 | |
Redundancy | 35.8 | |
CC(1/2) | 0.999 | 0.649 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100 mM MOPS, pH7, 500 mM NaCl |