8VDV
pcsk9 in complex with inhibitor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 17-ID |
Synchrotron site | APS |
Beamline | 17-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-11-14 |
Detector | DECTRIS EIGER R 1M |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 63.086, 70.846, 149.007 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 58.094 - 1.972 |
R-factor | 0.1872 |
Rwork | 0.186 |
R-free | 0.21680 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.010 |
RMSD bond angle | 1.520 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.8_1069) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 149.007 | 1.978 |
High resolution limit [Å] | 1.972 | 1.972 |
Rmerge | 0.087 | 0.631 |
Rmeas | 0.094 | 0.685 |
Rpim | 0.037 | 0.264 |
Total number of observations | 307800 | 3285 |
Number of reflections | 47937 | 496 |
<I/σ(I)> | 15.1 | 2.8 |
Completeness [%] | 100.0 | |
Redundancy | 6.4 | 6.6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | EVAPORATION | 298 | 20.0% Peg-6000, 0.1M Tris pH8.0 |