8UDN

A Stable Heterotrimeric Foldon with Minimum Mutation

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-B
Synchrotron siteAPS
Beamline23-ID-B
Temperature [K]100
Detector technologyPIXEL
Collection date2022-07-08
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.6199
Spacegroup nameP 43
Unit cell lengths32.854, 32.854, 75.230
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution22.200 - 0.970
R-factor0.1459
Rwork0.145
R-free0.15750
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.093
Data reduction softwareXDS (Jan 10, 2022 BUILT=20220220)
Data scaling softwareXDS (Jan 10, 2022 BUILT=20220220)
Phasing softwarePHASER (2.8.3)
Refinement softwarePHENIX ((1.20.1_4487: ???))
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]30.11030.1100.990
High resolution limit [Å]0.9704.3300.970
Rmerge0.0580.0241.274
Rmeas0.0600.0251.320
Number of reflections467275563444
<I/σ(I)>17.4
Completeness [%]99.098.998.3
Redundancy14
CC(1/2)1.0000.9990.759
Crystallization Conditions