8TOA
CryoEM structure of H7 hemagglutinin from A/Shanghai2/2013 H7N9 in complex with a human neutralizing antibody H7.HK2
EM specimen
| Vitrification | Yes |
EM Data Collection
| Microscope | FEI TITAN KRIOS |
| Electron Gun | FIELD EMISSION GUN |
| Accelerating Voltage (kV) | 300 |
| Detector | GATAN K3 BIOQUANTUM (6k x 4k) |
3D Reconstruction
| Method | SINGLE PARTICLE |
| Resolution (Å) | 3.69 |
| Software | cryoSPARC,Leginon |
| CTF correction | PHASE FLIPPING AND AMPLITUDE CORRECTION |