8TFR
Apo Fab from C10-S66K antibody
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 23-ID-D |
| Synchrotron site | APS |
| Beamline | 23-ID-D |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-04-16 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 1.03321 |
| Spacegroup name | P 62 |
| Unit cell lengths | 92.913, 92.913, 123.951 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 49.100 - 2.990 |
| R-factor | 0.2141 |
| Rwork | 0.211 |
| R-free | 0.26220 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.724 |
| Data reduction software | HKL-2000 |
| Data scaling software | SCALEPACK |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.19_4092) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 3.010 |
| High resolution limit [Å] | 2.960 | 2.960 |
| Number of reflections | 12321 | 596 |
| <I/σ(I)> | 13.1 | |
| Completeness [%] | 99.9 | |
| Redundancy | 7.1 | |
| CC(1/2) | 0.989 | 0.502 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293.15 | 20% PEG 3350, 0.2 M Na3-citrate, pH 8.2 |