8TFR
Apo Fab from C10-S66K antibody
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-D |
Synchrotron site | APS |
Beamline | 23-ID-D |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-04-16 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 1.03321 |
Spacegroup name | P 62 |
Unit cell lengths | 92.913, 92.913, 123.951 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 49.100 - 2.990 |
R-factor | 0.2141 |
Rwork | 0.211 |
R-free | 0.26220 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.004 |
RMSD bond angle | 0.724 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | PHENIX (1.19_4092) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.010 |
High resolution limit [Å] | 2.960 | 2.960 |
Number of reflections | 12321 | 596 |
<I/σ(I)> | 13.1 | |
Completeness [%] | 99.9 | |
Redundancy | 7.1 | |
CC(1/2) | 0.989 | 0.502 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293.15 | 20% PEG 3350, 0.2 M Na3-citrate, pH 8.2 |