8TBJ
Tricomplex of RMC-7977, KRAS G12A, and CypA
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | CLSI BEAMLINE 08ID-1 |
| Synchrotron site | CLSI |
| Beamline | 08ID-1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-06-16 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 0.95375 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 65.450, 81.460, 127.225 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 63.610 - 1.450 |
| R-factor | 0.1868 |
| Rwork | 0.185 |
| R-free | 0.21550 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.016 |
| RMSD bond angle | 1.523 |
| Data reduction software | HKL-2000 |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 63.610 | 1.502 |
| High resolution limit [Å] | 1.450 | 1.450 |
| Rmerge | 0.104 | 1.363 |
| Rmeas | 0.112 | 1.463 |
| Rpim | 0.041 | 0.529 |
| Number of reflections | 120928 | 11961 |
| <I/σ(I)> | 8.48 | 1.18 |
| Completeness [%] | 99.9 | 99.85 |
| Redundancy | 7.3 | 7.6 |
| CC(1/2) | 0.998 | 0.552 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 8 | 291 | 24% PEG4000, 0.1 M Tris-HCl, pH 8.0 |