8SZP
Human DHX9 bound to ADP
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I03 |
| Synchrotron site | Diamond |
| Beamline | I03 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-05-05 |
| Detector | DECTRIS EIGER2 XE 16M |
| Wavelength(s) | 0.97624 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 119.100, 122.260, 349.180 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 59.621 - 2.620 |
| Rwork | 0.219 |
| R-free | 0.27360 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.877 |
| Data reduction software | xia2 |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0405) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 61.130 | 2.670 |
| High resolution limit [Å] | 2.620 | 2.620 |
| Rmerge | 0.062 | 1.398 |
| Rmeas | 0.064 | 1.450 |
| Rpim | 0.018 | 0.382 |
| Total number of observations | 980269 | 63231 |
| Number of reflections | 76541 | 4516 |
| <I/σ(I)> | 21.8 | 2.2 |
| Completeness [%] | 99.7 | |
| Redundancy | 12.8 | 14 |
| CC(1/2) | 1.000 | 0.815 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 6 | 291 | 200 mM Lithium sulfate, 100 mM MES pH 6, 20% (w/v) PEG 4000; 5 mM ADP and 50 mM magnesium chloride in protein solution |