8STI
human STING with agonist XMT-1616
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X10SA |
Synchrotron site | SLS |
Beamline | X10SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-09-17 |
Detector | DECTRIS EIGER2 S 16M |
Wavelength(s) | 1.0000 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 111.519, 111.519, 35.806 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 78.860 - 1.720 |
R-factor | 0.21227 |
Rwork | 0.207 |
R-free | 0.25697 |
Structure solution method | MIR |
RMSD bond length | 0.011 |
RMSD bond angle | 1.521 |
Data reduction software | autoPROC |
Data scaling software | autoPROC ((Version 1.1.7)) |
Phasing software | REFMAC |
Refinement software | REFMAC (5.8.0155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 78.860 | 78.860 |
High resolution limit [Å] | 1.720 | 1.720 |
Number of reflections | 24490 | 24490 |
<I/σ(I)> | 24 | |
Completeness [%] | 99.6 | |
Redundancy | 15.8 | |
CC(1/2) | 1.000 | 1.000 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | PEG 3350; ammonium tartrate |