8SCM
Bst DNA polymerase I Large Fragment mutant F710Y/D598A with 3'-amino primer, dGTP, and calcium time-resolved 8h
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 8.2.2 |
Synchrotron site | ALS |
Beamline | 8.2.2 |
Temperature [K] | 99 |
Detector technology | CCD |
Collection date | 2020-10-01 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1.0000 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 93.966, 109.484, 149.824 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 44.100 - 2.300 |
R-factor | 0.196 |
Rwork | 0.193 |
R-free | 0.24950 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 0.927 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.340 |
High resolution limit [Å] | 2.300 | 2.300 |
Rmerge | 0.088 | 0.498 |
Rmeas | 0.100 | 0.567 |
Rpim | 0.046 | 0.266 |
Number of reflections | 67705 | 3421 |
<I/σ(I)> | 14.4 | 3 |
Completeness [%] | 97.7 | 100 |
Redundancy | 4.8 | 4.8 |
CC(1/2) | 0.986 | 0.778 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 2M ammonium sulphate, 0.1M MES pH 5.3-6.0, 20 mM CaCl2, 5% MPD |