Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

8S7A

HSPB8acd-C99S/F155T/A156S

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2022-10-18
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9795
Spacegroup nameI 41 2 2
Unit cell lengths98.273, 98.273, 42.958
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution34.745 - 1.951
R-factor0.2301
Rwork0.228
R-free0.26580
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.004
RMSD bond angle0.707
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwarePHASER
Refinement softwarePHENIX ((1.12_2829: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]34.7455.290
High resolution limit [Å]1.9501.950
Rmerge0.0544.188
Number of reflections7957389
<I/σ(I)>19.60.3
Completeness [%]100.0100
Redundancy13.113.6
CC(1/2)1.0000.285
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2950.2 M lithium sulfate monohydrate 0.1 M Tris pH 8.5 1.26 M ammonium sulfate

237735

PDB entries from 2025-06-18