Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I04-1 |
Synchrotron site | Diamond |
Beamline | I04-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-08-12 |
Detector | DECTRIS EIGER2 XE 9M |
Wavelength(s) | .92819 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 46.572, 216.554, 56.070 |
Unit cell angles | 90.00, 96.69, 90.00 |
Refinement procedure
Resolution | 108.280 - 2.170 |
R-factor | 0.18289 |
Rwork | 0.180 |
R-free | 0.23148 |
Structure solution method | FOURIER SYNTHESIS |
RMSD bond length | 0.009 |
RMSD bond angle | 1.287 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | CSearch |
Refinement software | REFMAC |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 108.280 | 2.210 |
High resolution limit [Å] | 2.170 | 2.170 |
Rmeas | 0.074 | 1.090 |
Number of reflections | 57530 | 3073 |
<I/σ(I)> | 7.4 | |
Completeness [%] | 99.8 | 99.8 |
Redundancy | 3.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 293 | 0.5M K formate 15% PEG 3350 0.1M pH=8 Bis-Tris propane/HCl |