8RBK
Bos taurus PRMT9 in the presence of SAH
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 2 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-09-22 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 0.980115 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 151.433, 121.247, 67.355 |
Unit cell angles | 90.00, 113.32, 90.00 |
Refinement procedure
Resolution | 45.970 - 3.600 |
R-factor | 0.2409 |
Rwork | 0.239 |
R-free | 0.27890 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.002 |
RMSD bond angle | 0.529 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHENIX (1.19.2) |
Refinement software | PHENIX (1.19rc4_4035) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 45.970 | 3.940 |
High resolution limit [Å] | 3.600 | 3.600 |
Rmerge | 0.105 | 2.446 |
Rmeas | 0.114 | 2.650 |
Rpim | 0.043 | 1.012 |
Total number of observations | 90508 | 21045 |
Number of reflections | 12994 | 3096 |
<I/σ(I)> | 8.4 | 0.8 |
Completeness [%] | 99.7 | |
Redundancy | 7 | 6.8 |
CC(1/2) | 0.997 | 0.516 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 100 mM Tris pH 7.5 0.8 M A.S. 2.5% PEG 6,000 |