8QRL
mt-SSU assembly intermediate in GTPBP8 knock-out cells, state 2
EM specimen
Vitrification | Yes |
EM Data Collection
Microscope | TFS KRIOS |
Electron Gun | FIELD EMISSION GUN |
Accelerating Voltage (kV) | 300 |
Detector | GATAN K3 BIOQUANTUM (6k x 4k) |
3D Reconstruction
Method | SINGLE PARTICLE |
Resolution (Å) | 3.34 |
Number of Particle | 435172 |
Software | cryoSPARC |
CTF correction | PHASE FLIPPING AND AMPLITUDE CORRECTION |