8QJ4

Receptor Sd-Amt1 (ON-state)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]100
Detector technologyPIXEL
Collection date2021-12-25
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)1
Spacegroup nameH 3
Unit cell lengths115.098, 115.098, 275.718
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution49.090 - 1.700
R-factor0.15063
Rwork0.150
R-free0.16615
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.012
RMSD bond angle1.710
Data reduction softwareHKL-2000
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0419)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.780
High resolution limit [Å]1.6501.750
Rmerge0.1061.693
Rmeas0.1121.803
Rpim0.0350.614
Total number of observations57709
Number of reflections1372066813
<I/σ(I)>13.21.3
Completeness [%]100.0
Redundancy10.38.5
CC(1/2)0.9990.529
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.52930.1 M Bis/Tris pH 6.5 with 25 % (w/v) PEG 3350

222624

PDB entries from 2024-07-17

PDB statisticsPDBj update infoContact PDBjnumon