Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8QD5

AntI Ser245DHA (PSF)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2021-03-20
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.0
Spacegroup nameC 2 2 21
Unit cell lengths54.570, 154.600, 91.460
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution44.850 - 1.800
R-factor0.16332
Rwork0.162
R-free0.19597
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.003
RMSD bond angle1.203
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0267)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.900
High resolution limit [Å]1.8001.800
Rmerge0.0460.643
Number of reflections357485333
<I/σ(I)>18.22.3
Completeness [%]98.499.4
Redundancy4.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.1293100 mM HEPES pH 7.1, 0.1 M NaAc pH 6.6, 24% PEG 3350

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon