8POJ
TEAD2 in complex with an inhibitor
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ESRF BEAMLINE BM30A |
| Synchrotron site | ESRF |
| Beamline | BM30A |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2023-06-10 |
| Detector | PSI PILATUS 6M |
| Wavelength(s) | 0.9697 |
| Spacegroup name | C 1 2 1 |
| Unit cell lengths | 121.146, 61.686, 79.980 |
| Unit cell angles | 90.00, 117.35, 90.00 |
Refinement procedure
| Resolution | 48.390 - 2.450 |
| R-factor | 0.2199 |
| Rwork | 0.217 |
| R-free | 0.26840 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.066 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.20.1_4487: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 48.390 | 2.540 |
| High resolution limit [Å] | 2.450 | 2.450 |
| Number of reflections | 31478 | 1816 |
| <I/σ(I)> | 9.74 | |
| Completeness [%] | 93.7 | |
| Redundancy | 2.5 | |
| CC(1/2) | 0.994 | 0.572 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 298 | 2.8M sodium formate |