8PJP
Neisseria meningitidis PilE, SB-GATDH variant, bound to the F10 nanobody
EM specimen
| Vitrification | Yes |
EM Data Collection
| Microscope | FEI TITAN KRIOS |
| Electron Gun | FIELD EMISSION GUN |
| Accelerating Voltage (kV) | 300 |
| Detector | GATAN K3 (6k x 4k) |
3D Reconstruction
| Method | HELICAL |
| Resolution (Å) | 2.92 |
| CTF correction | PHASE FLIPPING AND AMPLITUDE CORRECTION |