8KBM
Structure of AcrIIA7 complexed with cGG
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL19U1 |
Synchrotron site | SSRF |
Beamline | BL19U1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-12-23 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.979 |
Spacegroup name | C 2 2 2 |
Unit cell lengths | 88.065, 89.846, 63.214 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 19.770 - 1.380 |
R-factor | 0.2035 |
Rwork | 0.203 |
R-free | 0.21810 |
Structure solution method | SAD |
RMSD bond length | 0.012 |
RMSD bond angle | 1.398 |
Data reduction software | xia2 |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | PHENIX ((1.18.2_3874: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 19.770 | 1.450 |
High resolution limit [Å] | 1.380 | 1.380 |
Rmeas | 0.109 | 1.718 |
Number of reflections | 97761 | 4952 |
<I/σ(I)> | 15 | 2 |
Completeness [%] | 97.9 | |
Redundancy | 26.4 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291 | 1.0 M Lithium chloride, 20% w/v Polyethylene glycol 6000 |