Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8IS6

Apo-CrtMLIKE

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPAL/PLS BEAMLINE 11C
Synchrotron sitePAL/PLS
Beamline11C
Temperature [K]100
Detector technologyPIXEL
Collection date2023-02-28
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9794
Spacegroup nameC 2 2 21
Unit cell lengths50.610, 64.897, 170.277
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution42.570 - 2.000
R-factor0.1971
Rwork0.192
R-free0.24660
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle0.920
Data scaling softwareHKL-3000
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.18.2_3874: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0002.030
High resolution limit [Å]2.0002.000
Rmeas0.1340.481
Number of reflections19434981
<I/σ(I)>49.338.3
Completeness [%]99.8
Redundancy12.6
CC(1/2)0.9910.978
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2930.1M Tris, 30% PEG 4000, 0.2M MgCl2, pH 8.5

223166

PDB entries from 2024-07-31

PDB statisticsPDBj update infoContact PDBjnumon