8IK1
EstL5 in complex of PMSF
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL18U1 |
Synchrotron site | SSRF |
Beamline | BL18U1 |
Temperature [K] | 93 |
Detector technology | PIXEL |
Collection date | 2022-11-11 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.97 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 105.153, 105.153, 128.001 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 29.510 - 2.350 |
R-factor | 0.2126 |
Rwork | 0.211 |
R-free | 0.24970 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.002 |
RMSD bond angle | 0.506 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.1) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 105.150 | 2.470 |
High resolution limit [Å] | 2.350 | 2.350 |
Rmeas | 0.047 | |
Number of reflections | 29348 | 4241 |
<I/σ(I)> | 20.7 | |
Completeness [%] | 96.3 | 96.9 |
Redundancy | 8.7 | 7.8 |
CC(1/2) | 0.999 | 0.870 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.01 M CoCl2-6H2O, pH 4.8 0.1 M Sodium acetate and 1 M 1,6-Hexanediol |