8I4O
Design of a split green fluorescent protein for sensing and tracking an beta-amyloid
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PAL/PLS BEAMLINE 5C (4A) |
Synchrotron site | PAL/PLS |
Beamline | 5C (4A) |
Temperature [K] | 110 |
Detector technology | PIXEL |
Collection date | 2022-03-21 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 1.00003 |
Spacegroup name | P 1 |
Unit cell lengths | 64.804, 68.819, 101.239 |
Unit cell angles | 98.38, 97.97, 113.44 |
Refinement procedure
Resolution | 33.940 - 3.100 |
R-factor | 0.2562 |
Rwork | 0.252 |
R-free | 0.32340 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.012 |
RMSD bond angle | 1.476 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Refinement software | PHENIX ((1.18.2_3874: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 7.590 |
High resolution limit [Å] | 2.800 | 2.800 |
Number of reflections | 25720 | 35216 |
<I/σ(I)> | 10.8 | |
Completeness [%] | 91.5 | |
Redundancy | 3.5 | |
CC(1/2) | 0.975 | 0.975 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 100mM imidazole pH 8.0, 200mM Zn(OAc)2, 20% 1,4-butanediol |