8HQ8
Bry-LHCII homotrimer of Bryopsis corticulans
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SPRING-8 BEAMLINE BL41XU |
Synchrotron site | SPring-8 |
Beamline | BL41XU |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2014-07-02 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 109.720, 91.610, 169.220 |
Unit cell angles | 90.00, 103.52, 90.00 |
Refinement procedure
Resolution | 39.900 - 2.600 |
R-factor | 0.2083 |
Rwork | 0.207 |
R-free | 0.24930 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.021 |
RMSD bond angle | 1.233 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | PHENIX ((1.18_3861: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.000 | 2.690 |
High resolution limit [Å] | 2.600 | 2.600 |
Rmerge | 0.062 | 0.062 |
Rpim | 0.026 | |
Number of reflections | 68491 | 1284 |
<I/σ(I)> | 13.84 | |
Completeness [%] | 94.3 | |
Redundancy | 6.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | HEPES, PEG 1000, magnesium chloride,betaine, Cymal3 |