8GV4
A human broadly neutralizing influenza A hemagglutinin stem-specific antibody PN-SIA28
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL17U1 |
| Synchrotron site | SSRF |
| Beamline | BL17U1 |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2016-09-06 |
| Detector | ADSC QUANTUM 315 |
| Wavelength(s) | 1.03906 |
| Spacegroup name | P 1 21 1 |
| Unit cell lengths | 76.560, 86.361, 82.895 |
| Unit cell angles | 90.00, 105.29, 90.00 |
Refinement procedure
| Resolution | 42.140 - 2.500 |
| R-factor | 0.1967 |
| Rwork | 0.195 |
| R-free | 0.22980 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 5gjs |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.655 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.20_4459) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 2.590 |
| High resolution limit [Å] | 2.500 | 2.500 |
| Rmerge | 0.120 | 0.390 |
| Number of reflections | 36196 | 7086 |
| <I/σ(I)> | 15.4 | 7.9 |
| Completeness [%] | 97.9 | |
| Redundancy | 6.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.1M HEPES pH7.0, 12% PEG 3350 |