8GTF
Cryo-EM model of the marine siphophage vB_DshS-R4C stopper-terminator complex
This is a non-PDB format compatible entry.
EM specimen
| Vitrification | Yes |
EM Data Collection
| Microscope | FEI TECNAI F30 |
| Electron Gun | FIELD EMISSION GUN |
| Accelerating Voltage (kV) | 300 |
| Detector | FEI FALCON III (4k x 4k) |
3D Reconstruction
| Method | SINGLE PARTICLE |
| Resolution (Å) | 6.6 |
| Symmetry | C6 |
| CTF correction | PHASE FLIPPING AND AMPLITUDE CORRECTION |