8FUW
KpsC D160N Kdo adduct
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | CLSI BEAMLINE 08ID-1 |
| Synchrotron site | CLSI |
| Beamline | 08ID-1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2020-03-01 |
| Detector | DECTRIS EIGER X 9M |
| Wavelength(s) | 0.98011 |
| Spacegroup name | P 31 2 1 |
| Unit cell lengths | 64.380, 64.380, 139.200 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 46.400 - 1.900 |
| R-factor | 0.1923 |
| Rwork | 0.191 |
| R-free | 0.22570 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.010 |
| RMSD bond angle | 0.964 |
| Data reduction software | XDS |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.19_4092) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 46.400 | 1.950 |
| High resolution limit [Å] | 1.900 | 1.900 |
| Rmeas | 0.084 | 2.660 |
| Number of reflections | 27085 | 2008 |
| <I/σ(I)> | 12.74 | 1.09 |
| Completeness [%] | 99.9 | 100 |
| Redundancy | 9.6 | 9.6 |
| CC(1/2) | 0.998 | 0.542 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 5.5 | 293 | 0.2 M lithium sulfate, 29 % (v/v) PEG 3350 and 0.1 M Bis-Tris, pH 5.5 and 2 mM strontium acetate |