8F9D
Compound 21 bound to procaspase-6
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-ID |
Synchrotron site | APS |
Beamline | 19-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-07-31 |
Detector | DECTRIS PILATUS3 X 6M |
Wavelength(s) | 0.979180 |
Spacegroup name | P 61 |
Unit cell lengths | 101.529, 101.529, 321.926 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 48.460 - 2.650 |
R-factor | 0.1951 |
Rwork | 0.193 |
R-free | 0.22940 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.008 |
RMSD bond angle | 1.519 |
Data reduction software | XDS |
Data scaling software | Aimless (0.7.7) |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0238) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.410 | 2.730 |
High resolution limit [Å] | 2.650 | 2.650 |
Rmerge | 0.154 | 1.685 |
Rmeas | 0.159 | 1.740 |
Rpim | 0.040 | 0.431 |
Total number of observations | 852492 | 72174 |
Number of reflections | 54317 | 4446 |
<I/σ(I)> | 15.2 | 1.8 |
Completeness [%] | 99.9 | |
Redundancy | 15.7 | 16.2 |
CC(1/2) | 0.999 | 0.886 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 277 | 0.1 M HEPES pH 7, 4% w/v PEG 8000 |