8EGX
Complex of Fat4(EC1-4) bound to Dchs1(EC1-4)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-BM |
Synchrotron site | APS |
Beamline | 22-BM |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2018-12-03 |
Detector | RAYONIX MX300-HS |
Wavelength(s) | 1 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 64.222, 82.102, 224.759 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.350 | 3.820 |
High resolution limit [Å] | 3.688 | 3.688 |
Number of reflections | 12968 | 1214 |
<I/σ(I)> | 4.05 | |
Completeness [%] | 95.9 | |
Redundancy | 2 | |
CC(1/2) | 0.994 | 0.998 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293.15 | 0.1 M MES, pH 6.5; 0.2 M Sodium Chloride; 10% PEG 4000 |