Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 120 |
Detector technology | PIXEL |
Collection date | 2022-07-22 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.97918 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 70.243, 70.243, 287.353 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 68.230 - 2.500 |
R-factor | 0.222 |
Rwork | 0.220 |
R-free | 0.25880 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | AlphaFold2 model for UNC-6 |
RMSD bond length | 0.008 |
RMSD bond angle | 0.899 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 200.000 | 2.650 |
High resolution limit [Å] | 2.500 | 2.500 |
Rmerge | 0.087 | 2.164 |
Rmeas | 0.090 | 2.245 |
Number of reflections | 25806 | 4008 |
<I/σ(I)> | 19.43 | 1.25 |
Completeness [%] | 98.8 | 98.3 |
Redundancy | 13.1 | 13.7 |
CC(1/2) | 0.999 | 0.700 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 295 | 0.1 M Tris, pH 8.0, 10% (w/v) Polyethylene glycol 8,000 |