Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8DDK

CCHFV GP38 Hoti/Kosovo bound with CC5_17

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 22-ID
Synchrotron siteAPS
Beamline22-ID
Temperature [K]100
Detector technologyCCD
Collection date2021-12-11
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)1.0
Spacegroup nameP 43 21 2
Unit cell lengths175.676, 175.676, 92.158
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution43.070 - 3.860
R-factor0.3052
Rwork0.304
R-free0.33470
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)8dc5
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX (1.20.1_4487)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0003.920
High resolution limit [Å]3.8503.850
Rpim0.1000.480
Number of reflections139421363
<I/σ(I)>21.8
Completeness [%]98.6
Redundancy7.8
CC(1/2)0.8810.763
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP293.1520% PEG1000, and 0.1M HEPES pH 6.4

222415

PDB entries from 2024-07-10

PDB statisticsPDBj update infoContact PDBjnumon