8CM1
Lol B - Localization of lipoprotein B from Vibrio cholera
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | MAX IV BEAMLINE BioMAX |
Synchrotron site | MAX IV |
Beamline | BioMAX |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-07-09 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.97624 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 113.414, 113.414, 34.150 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 35.860 - 1.460 |
R-factor | 0.1673 |
Rwork | 0.166 |
R-free | 0.19720 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.006 |
RMSD bond angle | 0.955 |
Data reduction software | autoPROC (1.20.1-4487) |
Data scaling software | autoPROC (1.20.1-4487) |
Phasing software | PHENIX (1.19.2-4158) |
Refinement software | PHENIX (1.19.2-4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 40.100 | 1.512 |
High resolution limit [Å] | 1.460 | 1.460 |
Rmerge | 0.127 | 0.374 |
Rmeas | 0.132 | 0.529 |
Rpim | 0.026 | 0.374 |
Number of reflections | 39405 | 3862 |
<I/σ(I)> | 19.6 | 1.69 |
Completeness [%] | 100.0 | 99.97 |
Redundancy | 2 | |
CC(1/2) | 0.999 | 0.752 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 291.15 | 0.1M KCl, 0.1 M Bis-Tris 6.0, 18% w/v PEG4000 |