8BYO
fragment-linked stabilizer for ERa - 14-3-3 interaction (1074361)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I24 |
| Synchrotron site | Diamond |
| Beamline | I24 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2020-02-28 |
| Detector | DECTRIS EIGER2 S 9M |
| Wavelength(s) | 0.97629 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 81.839, 112.354, 62.477 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 34.230 - 1.200 |
| R-factor | 0.1646 |
| Rwork | 0.164 |
| R-free | 0.17100 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.008 |
| RMSD bond angle | 0.982 |
| Data reduction software | DIALS |
| Data scaling software | XDS |
| Phasing software | MOLREP |
| Refinement software | PHENIX (1.19.2-4158) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 41.830 | 1.220 |
| High resolution limit [Å] | 1.200 | 1.200 |
| Number of reflections | 90431 | 4402 |
| <I/σ(I)> | 18.6 | |
| Completeness [%] | 100.0 | |
| Redundancy | 12.9 | |
| CC(1/2) | 1.000 | 0.877 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |