8BXS
Fragment-linked stabilizer for ERa - 14-3-3 interaction (1075293)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PETRA III, DESY BEAMLINE P11 |
Synchrotron site | PETRA III, DESY |
Beamline | P11 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-08-23 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 1.033 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 82.050, 112.346, 62.415 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 41.750 - 1.600 |
R-factor | 0.1666 |
Rwork | 0.165 |
R-free | 0.19120 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.009 |
RMSD bond angle | 1.117 |
Data reduction software | DIALS |
Data scaling software | XDS |
Phasing software | MOLREP |
Refinement software | PHENIX (1.19.2-4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 41.750 | 1.630 |
High resolution limit [Å] | 1.600 | 1.600 |
Number of reflections | 37816 | 1818 |
<I/σ(I)> | 33 | |
Completeness [%] | 98.4 | |
Redundancy | 12.9 | |
CC(1/2) | 0.999 | 0.987 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 277 | 0.095 M HEPES (pH 7.1), PEG400 (24% (v/v)), 0.19 M CaCl2 and 5% (v/v) Glycerol |