Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8BBB

IPNS H270A variant in complex with ACV exposed to O2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyPIXEL
Collection date2022-09-13
DetectorDECTRIS EIGER2 XE 16M
Wavelength(s)0.9763
Spacegroup nameP 21 21 21
Unit cell lengths41.300, 74.250, 101.010
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution41.760 - 1.570
R-factor0.1798
Rwork0.178
R-free0.20530
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6zae
Data reduction softwareDIALS
Data scaling softwareAimless (0.7.9)
Phasing softwarePHASER
Refinement softwarePHENIX (1.19.2_4158)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]41.76041.7601.610
High resolution limit [Å]1.5707.0201.570
Rmerge0.2170.0473.415
Rmeas0.2260.0493.564
Rpim0.0620.0141.008
Total number of observations588792
Number of reflections442495883213
<I/σ(I)>80.7
Completeness [%]100.099.899.6
Redundancy13.311.912.2
CC(1/2)0.9980.9990.512
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1BATCH MODE8.32981.7 M Li2SO4, 0.1 M Tris pH 8.3

223532

PDB entries from 2024-08-07

PDB statisticsPDBj update infoContact PDBjnumon