8AZX

KRAS-G12C in complex with BI-2865

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2022-03-18
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.000004
Spacegroup nameP 21 21 2
Unit cell lengths86.505, 40.645, 56.018
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution36.790 - 1.040
R-factor0.1629
Rwork0.161
R-free0.19700
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)8afb
RMSD bond length0.009
RMSD bond angle1.104
Data reduction softwareXDS
Data scaling softwareSTARANISO
Phasing softwarePHASER
Refinement softwarePHENIX (1.20_4459)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]56.0201.171
High resolution limit [Å]1.0401.042
Rmerge0.0570.864
Number of reflections568892845
<I/σ(I)>17.42.2
Completeness [%]94.668.3
Redundancy12.39.6
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2770.2mM Magnesium Chloride, 20% PEG 2000, 100mM sodium acetate pH 4.4

237992