Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8ARX

Small molecular stabilizer for ERalpha and 14-3-3sigma (1074378)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPETRA III, DESY BEAMLINE P11
Synchrotron sitePETRA III, DESY
BeamlineP11
Temperature [K]100
Detector technologyPIXEL
Collection date2021-11-04
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.033220
Spacegroup nameC 2 2 21
Unit cell lengths81.979, 112.338, 62.521
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution45.500 - 1.400
R-factor0.1387
Rwork0.137
R-free0.16535
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4jc3
RMSD bond length0.014
RMSD bond angle1.609
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0267)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.5001.420
High resolution limit [Å]1.4001.400
Number of reflections570032724
<I/σ(I)>49.7
Completeness [%]99.8
Redundancy6.9
CC(1/2)1.0000.988
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2770.095 M HEPES (pH 7.1), PEG400 (24% (v/v)), 0.19 M CaCl2 and 5% (v/v) Glycerol

222415

PDB entries from 2024-07-10

PDB statisticsPDBj update infoContact PDBjnumon