Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

8AJ1

SARS-CoV-2 Mpro in Complex with RK-107

This is a non-PDB format compatible entry.
Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPETRA III, DESY BEAMLINE P11
Synchrotron sitePETRA III, DESY
BeamlineP11
Temperature [K]100
Detector technologyPIXEL
Collection date2021-12-06
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.0332
Spacegroup nameC 1 2 1
Unit cell lengths113.234, 52.955, 45.707
Unit cell angles90.00, 102.81, 90.00
Refinement procedure
Resolution47.793 - 2.600
Rwork0.195
R-free0.27450
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.004
RMSD bond angle1.122
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareMOLREP
Refinement softwareREFMAC (5.8.0419)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.7932.690
High resolution limit [Å]2.6002.600
Number of reflections8125825
<I/σ(I)>7.1
Completeness [%]98.098
Redundancy3.5
CC(1/2)0.9960.508
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP72930.1M PCTP pH7.0, 25% w/vPEG 1500

225946

PDB entries from 2024-10-09

PDB statisticsPDBj update infoContact PDBjnumon