8AIF
TapA acts as specific chaperone in TasA non-amyloid filament formation
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | BESSY BEAMLINE 14.1 |
Synchrotron site | BESSY |
Beamline | 14.1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-05-27 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.91841 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 39.199, 52.936, 167.763 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 38.440 - 1.070 |
R-factor | 0.1486 |
Rwork | 0.148 |
R-free | 0.17660 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6hqc |
RMSD bond length | 0.012 |
RMSD bond angle | 1.655 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 38.440 | 1.130 |
High resolution limit [Å] | 1.070 | 1.070 |
Rmeas | 0.066 | 0.154 |
Number of reflections | 153127 | 24261 |
<I/σ(I)> | 9.77 | |
Completeness [%] | 98.8 | |
Redundancy | 3.53 | |
CC(1/2) | 0.999 | 0.300 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 24% PEG3350, 0.35M LiNO3 |