8AHH
PAC FragmentDEL: Photoactivated covalent capture of DNA encoded fragments for hit discovery
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I03 |
| Synchrotron site | Diamond |
| Beamline | I03 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2021-09-19 |
| Detector | DECTRIS EIGER2 XE 16M |
| Wavelength(s) | 0.9763 |
| Spacegroup name | P 41 21 2 |
| Unit cell lengths | 61.897, 61.897, 180.162 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 58.539 - 2.037 |
| Rwork | 0.184 |
| R-free | 0.25010 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 2bva |
| RMSD bond length | 0.009 |
| RMSD bond angle | 1.531 |
| Data reduction software | XDS (Fe5 5, 2021) |
| Data scaling software | Aimless (V0.7.7) |
| Refinement software | REFMAC (5.8.0352) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 58.589 | 2.173 |
| High resolution limit [Å] | 2.037 | 2.037 |
| Rmerge | 0.097 | 2.747 |
| Rmeas | 0.099 | 2.801 |
| Rpim | 0.019 | 0.542 |
| Number of reflections | 20091 | 1005 |
| <I/σ(I)> | 21.4 | 1.4 |
| Completeness [%] | 94.6 | 52.6 |
| Redundancy | 26 | 26.3 |
| CC(1/2) | 1.000 | 0.699 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 277 | 0.8M Na/K tartrate 0.1M Tris pH 8.5 |