8YIV
N17.1.2 recognition of NRAS neoantigens
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 23-ID-B |
Synchrotron site | APS |
Beamline | 23-ID-B |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-02-14 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9793 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 71.144, 133.223, 222.468 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 42.692 - 2.101 |
R-factor | 0.1925 |
Rwork | 0.191 |
R-free | 0.22590 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.011 |
RMSD bond angle | 1.131 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX ((1.16_3549: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 42.700 | 2.180 |
High resolution limit [Å] | 2.100 | 2.100 |
Number of reflections | 387710 | |
<I/σ(I)> | 13.7 | |
Completeness [%] | 99.8 | |
Redundancy | 6.3 | |
CC(1/2) | 0.992 | 0.857 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 10mg/ml, 8% TacsimateTM pH7.0, 20% PEG4K |