8YIV
N17.1.2 recognition of NRAS neoantigens
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 23-ID-B |
| Synchrotron site | APS |
| Beamline | 23-ID-B |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2022-02-14 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.9793 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 71.144, 133.223, 222.468 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 42.692 - 2.101 |
| R-factor | 0.1925 |
| Rwork | 0.191 |
| R-free | 0.22590 |
| Structure solution method | MOLECULAR REPLACEMENT |
| RMSD bond length | 0.011 |
| RMSD bond angle | 1.131 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHENIX |
| Refinement software | PHENIX ((1.16_3549: ???)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 42.700 | 2.180 |
| High resolution limit [Å] | 2.100 | 2.100 |
| Number of reflections | 387710 | |
| <I/σ(I)> | 13.7 | |
| Completeness [%] | 99.8 | |
| Redundancy | 6.3 | |
| CC(1/2) | 0.992 | 0.857 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 10mg/ml, 8% TacsimateTM pH7.0, 20% PEG4K |