8VCN
GluER mutant - W66F F269Y Q293T F68Y T36E P263L
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | NSLS-II BEAMLINE 17-ID-2 |
Synchrotron site | NSLS-II |
Beamline | 17-ID-2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2023-09-25 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.9793 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 54.887, 90.914, 74.872 |
Unit cell angles | 90.00, 110.13, 90.00 |
Refinement procedure
Resolution | 27.810 - 1.470 |
R-factor | 0.1587 |
Rwork | 0.157 |
R-free | 0.18380 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.005 |
RMSD bond angle | 0.886 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.17_3644) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 27.810 | 1.510 |
High resolution limit [Å] | 1.470 | 1.470 |
Rmerge | 0.112 | 0.742 |
Rmeas | 0.124 | 0.831 |
Rpim | 0.054 | 0.368 |
Number of reflections | 57386 | 3661 |
<I/σ(I)> | 9 | 1.7 |
Completeness [%] | 98.9 | 85.5 |
Redundancy | 5.1 | 4.8 |
CC(1/2) | 0.997 | 0.711 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4 | 293 | 4% v/v Tacsimate, pH 4.0, and 20% w/v polyethylene glycol 3350 |