8TAD
RTA in complex with inhibitor RUNT-206
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2022-09-16 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.979 |
Spacegroup name | P 63 2 2 |
Unit cell lengths | 169.877, 169.877, 54.639 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 49.040 - 2.760 |
R-factor | 0.221 |
Rwork | 0.219 |
R-free | 0.25610 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.003 |
RMSD bond angle | 0.576 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.20.1_4487) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 2.800 |
High resolution limit [Å] | 2.750 | 7.460 | 2.750 |
Rmerge | 0.085 | 3.232 | |
Rmeas | 0.087 | 3.290 | |
Rpim | 0.020 | 0.609 | |
Number of reflections | 12372 | 716 | 594 |
<I/σ(I)> | 2.2 | ||
Completeness [%] | 100.0 | 100 | 100 |
Redundancy | 20 | 19.2 | 27.8 |
CC(1/2) | 0.999 | 0.526 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 295 | 50 mM KH2PO4 and 20% PEG 8000 |